Oregon Scientific Weather Radio WMR968 User Manual

CABLE FREETM WEATHER  
STATION  
SECTION 2 INSTALLATION  
The WMR968 operates at 433MHz. No wire installation is required  
among units.  
MODEL: WMR968  
The WMR968 has an effective range of 109 yards in an open area.  
Position the units within the range and be sure the transmission  
path is clear of interference and obstacles.  
USER’S MANUAL  
Note:The anemometer, thermo-hygrometer and rain gauge should  
be installed outdoors and in locations that best measure the weather  
elements the instruments are designed for. As for the baro-thermo-  
hygrometer, it must be installed indoors. If you have any optional  
thermo or thermo-hygro sensors, they can be installed outdoors or  
indoors.  
SECTION 1 INTRODUCTION  
TM  
Congratulations on your purchasing the WMR968 Cable Free  
Weather Station. An all-purpose easy-to-use system, the WMR968  
lets you monitor the following weather elements:  
-
-
-
-
-
Air temperature  
Relative humidity  
Barometric pressure  
Wind speed and direction  
Rainfall  
The WMR968 is also equipped with:  
-
-
-
-
-
Calendar clock with daily alarm  
Weather forecast within 32 to 48 km (20- to 30-mile) radius  
Weather alarms  
Memory for maximum and minimum readings  
Simple, touch-screen operation  
-
-
RS232 PC connection jack  
backlight  
STANDARD PACKAGE  
The original WMR968 comes complete with the following:  
-
-
-
-
-
-
Main unit (WMR968)  
Anemometer(WGR968)  
Thermo-hygrometer(THGR968)  
Rain gauge (RGR968)  
Baro-thermo-hygrometer (BTHR968)  
12V AC adapter  
The thermo-hygrometer and rain gauge are powered by solar  
transmitters STR928 while the anemometer is powered by solar  
transmitter STR938.  
The WMR968 can support up to seven different remote instruments.  
You can also connect up to three optional thermo or thermo-hygro  
sensors to the system.  
THE ANEMOMETER  
The anemometer measures wind speed and direction.  
To install it,  
Optional items include:  
-
-
Thermo-hygro sensor (THGR238)  
Thermo sensor (THR238)  
1. Place the wind cup over the thinnest shaft on the anemometers  
T-bar.  
Contact an authorized dealer for optional items.  
2. Tighten the screw on the base of the wind cup.  
1
928N-USE.p65  
1
08/10/2001, 12:20 PM  
 
SECTION 3 OPERATION  
THE MAIN UNIT  
The main unit gives you all the readings and controls. It should be  
placed indoors.  
THE MAIN UNIT  
The main unit is powered up by the 12V AC adapter.  
To install it,  
1. Position the main unit and other units within effective range  
(109 yards).  
2. Insert four UM3 or AA-sized alkaline batteries for backup  
purpose.  
3. Mount the main unit safely in place. Or use its table stand to  
place it on a flat surface.  
A. WEATHER FORECAST AND BAROMETRIC READING  
WINDOW  
4. Connect the AC power adapter to the main unit and a wall socket.  
B. INDOOR TEMPERATURE WINDOW  
C. INDOOR HUMIDITY WINDOW  
D. OUTDOOR/CHANNEL TEMPERATURE WINDOW  
E. OUTDOOR/CHANNEL HUMIDITY WINDOW  
F. RAINFALL WINDOW  
G. CALENDAR CLOCK AND DAILY ALARM WINDOW  
H. WINDSPEED AND DIRECTION WINDOW  
I. CHANNEL BUTTON  
5. Press the [RESET] button on the main unit to initiate operation.  
J. MEMORY BUTTON  
The main unit will start searching for signals for about four minutes.  
Upon successful reception, the readings will be displayed. The  
main unit will update the readings at regular intervals.  
K. ALARM BUTTON  
L. SET BUTTON  
Note: That if the main unit is operating solely on battery power, the  
M. UNIT BUTTON  
EL backlight and RS232 connection will be disabled.  
N. ALARM ON/OFF BUTTON  
O. [U] BUTTON  
LOW-BATTERY WARNING  
P. [V] BUTTON  
There are low-battery indicators [  
] for the main unit, rain  
Q. [RESET] BUTTON  
gauge, baro-thermo-hygrometer, thermo-hygrometer and optional  
remote thermo and thermo-hygro sensors. Replace the batteries  
when the respective indicators light up.  
R. RS232 SERIAL PORT  
S. DC12VJACK  
Note: The readings collected from the thermo-hygrometer and any  
optional remote thermo and thermo-hygro sensors share the same  
displaywindow. TheOUTandremotechannelwillsharethesame  
low-battery indicator. When the battery level of the thermo-  
hygrometer is low, the low-battery indicator will turn on. If it is one  
of the optional remote sensors, the low-battery indicator will  
blink. To locate the channel in question, press the window to scan  
through all available devices. The low-battery indicator will stop  
blinking if the battery level is low for that one.  
3
928N-USE.p65  
3
08/10/2001, 12:20 PM  
 
5. Press [SET] for minutes setting.  
6. Use [U] and V] to change to the desired setting.  
7. Press [SET] to confirm.  
BACKLIGHT  
The main unit, when connected to the AC power, is equipped with  
an automatic backlight. Every time you press a window on the main  
Note: the window will show “  
if no alarm is armed.  
unit, the  
backlight will come on for a few seconds. This  
function will be disabled for sole battery operation. The  
backlight will also come on for a few seconds when the alarm is  
triggered.  
Once set, the alarm clock will be activated automatically and the  
alarm indicator  
will light up. When an alarm goes off, press any  
button to stop it. The alarm is still active and will go off again the  
next day.  
To deactivate the function,  
CALENDAR CLOCK  
1. Press the calendar clock and alarm window.  
To set the calendar clock,  
2. Press [ALARM ON/OFF]. The alarm indicator willdisappear.  
1. Press the calendar clock and alarm window.  
2. Press and hold [V] to disable the radio reception function.  
3. Press and hold [SET] till the digit flash.  
WEATHER FORECAST  
The weather forecast is displayed in the weather forecast and  
barometric reading window.  
4. Use [U] and [V] to change to the desired setting.  
5. Press [SET] for the next item setting.  
There are four readings for the forecast: sunny, slightly cloudy,  
cloudy and rainy.  
6. Repeat from Step 4 to finish all the settings for:  
-
-
-
-
-
Clock display formats (12hr or 24hr)  
Display language of the day-of-the-week  
Clock  
Indicator  
displays on  
the unit  
Forecast  
Sunny Slightly Cloudy Cloudy  
Rainy  
Calendar display formats (Month-Day, Day-Month)  
Calendar  
For the display language, you can choose:  
INDOOR BAROMETRIC READING  
-
-
-
-
-
English (E)  
German(D)  
French (F)  
Italian (I)  
The atmospheric pressure reading is displayed in the weather  
forecast and barometric reading window.  
The pressure reading can be displayed in mb (millibars), hPa  
(Hecto-Pascal), inHg(inchmercury)ormmHg(millimetermercury).  
To select the display unit,  
Spanish (S)  
1. Press the weather forecast and barometric reading window.  
7. Press [SET] to confirm.  
2. Press [UNIT] repeatedly for the desired setting.  
The calendar clock and alarm window has three displays: clock  
with seconds, clock with day-of-the-week and calendar. To change  
from one display to another, press the window once.  
The pressure history for the past 24 hours is displayed in a six-  
column bar chart.  
The calendar clock also supports the following time zones:  
To display the pressure reading for a particular hour within the  
past 24 hours,  
-
-
-
-
Pacific time (P)  
Mountain time (M)  
Central time (C)  
Eastern time (E)  
1. Press the weather forecast and barometric reading window.  
2. Press [U] and [V] for the desired hour.  
To set the sea-level pressure,  
1. Press the weather forecast and barometric reading window  
repeatedly till the sea-levelicon is displayed.  
To select a time zone,  
1. Press and hold the calendar clock and alarm window.  
2. Press [U] and [V] for the current (0 Hr) pressure.  
3. Press and hold [SET].  
2. Press [U] and [V] to change.  
3. Press the window again to confirm.  
4. Press [U] and [V] to change to the desired setting.  
5. Press [SET] to confirm.  
THE DAILY ALARM  
To set the daily alarm,  
INDOOR AND DEW POINT TEMPERATURES  
1. Press the calendar clock and alarm window.  
2. Press[ALARM]andthe  
you are in the alarm mode.  
indicatorwillbedisplaytoindicate  
The current indoor and dew point temperatures, taken by the indoor  
baro-thermo-hygrometer, are displayed on the indoor temperature  
window. They can be displayed in degree Centigrade (ºC) or  
Fahrenheit (ºF).  
3. Press and hold [SET] till the hour digit flash.  
4. Use [U] and [V] to change to the desired setting.  
4
928N-USE.p65  
4
08/10/2001, 12:20 PM  
 
To select the display unit,  
The temperatures can be displayed in degree Centigrade (°C) or  
Fahrenheit (°F).  
1. Press the indoor temperature window.  
To select the display unit,  
2. Press [UNIT] repeatedly for the desired setting. The selected unit  
will apply to all temperature displays in this window.  
1. Press the outdoor/channel temperature window.  
Note: The unit of all temperature related display will be changed  
simultaneously.  
2. Press [UNIT] repeatedly for the desired setting. The selected unit  
will apply to all temperature displays in this window.  
To display the dew point temperature, press the indoor temperature  
window until the DEWindicator is displayed.  
Note: The unit of all temperature related display will be changed  
simultaneously.  
Todisplaymaximum, minimumtemperatures,  
Todisplaythemaximum, minimum temperatures,  
1. Press the indoor temperature window or repeately until "DEW"  
icon appear.  
1. Press the outdoor/channel temperature window or repeately until  
"DEW" icon appear.  
2. Press[MEMORY]repeatedlyforthedesiredrecord. Thetimeand  
date of the record will also be displayed alternatively with  
STAMPicon in the clock window.  
2. Press [CHANNEL] for the outdoor thermo-hygrometer or the  
desired channel.  
3. Press[MEMORY]repeatedlyforthedesiredrecord. Thetimeand  
date of the record will also be displayed alternatively with  
STAMPicon in the clock window.  
The display will automatically return to the current temperature or  
dew temperature whatever is displayed before if the unit is left  
untouched for about one minute.  
To display the dew point temperature for a channel, press the  
window again when the channel temperature is located.  
To clear the memory,  
To clear the memory,  
1. Press the indoor temperature window or repeately until "DEW"  
icon appear.  
1. Press the outdoor/channel temperature window or repeately until  
"DEW" icon appear.  
2. Press and hold [MEMORY] till the key tone is heard.  
3. Press [MEMORY] to check the memory is clear.  
2. Press [CHANNEL] for the outdoor thermo-hygrometer or the  
desired channel.  
3. Press and hold [MEMORY] till the key tone is heard.  
4. Press [MEMORY] to check the memory is clear.  
INDOOR HUMIDITY  
The current indoor relative humidity, taken by the indoor baro-  
thermo-hygrometer, is displayed on the indoor hygrometer window.  
OUTDOOR AND CHANNEL HUMIDITY  
The relative humidity readings taken by the outdoor thermo-  
hygrometer and separate thermo-hygro sensors are displayed on  
the outdoor/channel humidity window.  
Todisplaythemaximum, minimumandcurrenthumidity,  
1. Press the indoor humidity window.  
As this window can display up to four different sets of data, specify  
the instrument or channel you want to read.  
2. Press[MEMORY]repeatedlyforthedesiredrecord. Thetimeand  
date of the record will also be displayed alternatively with  
STAMPicon in the clock window.  
To do so,  
To clear the memory,  
1. Press the outdoor/channel humidity window.  
1. Press the indoor humidity window.  
2. Press [CHANNEL] to go from the outdoor reading taken by the  
thermo-hygrometer to those taken by individual sensors  
(Channel 1, 2 or 3).  
2. Press and hold [MEMORY] till the key tone is heard.  
3. Press [MEMORY] to check the memory is clear.  
Todisplaythemaximum, minimumandcurrenthumidity,  
1. Press the outdoor/channel humidity window.  
OUTDOOR AND CHANNEL TEMPERATURES  
2. Press [CHANNEL] for the outdoor thermo-hygrometer or the  
desired channel.  
The temperature readings taken by the outdoor thermo-hygrometer  
and separate thermo or thermo-hygro sensors are displayed on the  
outdoor and channel temperature window.  
3. Press[MEMORY]repeatedlyforthedesiredrecord. Thetimeand  
date of the record will also be displayed alternatively with  
STAMPicon in the clock window.  
As this window can display up to four different sets of data, specify  
the instrument or channel you want to read.  
To clear the memory,  
To do so,  
1. Press the outdoor/channel humidity window.  
1. Press the outdoor/channel temperature window.  
2. Press [CHANNEL] for the outdoor thermo-hygrometer or the  
desired channel.  
2. Press [CHANNEL] to go from the outdoor reading taken by the  
outdoor thermo-hygrometer to those taken by individual sensors  
(Channel 1, 2 or 3).  
3. Press and hold [MEMORY] till the key tone is heard.  
4. Press [MEMORY] to check the memory is clear.  
The outdoor thermo-hygrometer is also capable of detecting the  
dew point temperature as well as the wind chill reading. To display  
such information, press the window repeatedly.  
5
928N-USE.p65  
5
08/10/2001, 12:20 PM  
 
To clear the record,  
AUTO SCANNING FUNCTION  
1. Press the wind speed and direction window.  
The auto scanning function is avalibable for the outdoor/channel  
window for both the temperature and humidity.  
2. Press and hold [MEMORY].  
As for the wind direction, it is displayed in a digital compass with  
bearing readouts.  
To use it,  
1. Press the outdoor/channel temperature or humidity window.  
2. Press and hold [U] . The main unit will start scanning from the  
active temperature and humidity display. Each channel will be  
displayed for about 4 seconds.  
WEATHER ALARMS  
Weather alarms are used to alert you to certain weather conditions.  
Once activated, the alarm will go off when a certain set criterion is  
met.  
To exit the auto scanning routine, press any window or control  
button.  
You can set alarms for:  
·
·
·
·
·
·
·
·
·
Indoor, outdoor and channel high temperatures  
Indoor, outdoor and channel low temperatures  
Indoor, outdoor and channel dew point approaching  
Indoor, outdoor and channel high humidity  
Indoor, outdoor and channel low humidity  
High rainfall rate  
RAINFALL  
The rate of rainfall can be displayed in mm/hr or in/hr.  
To select the display unit,  
1. Press the rainfall window.  
2. Press [UNIT] for the desired setting.  
To display the yesterdays rainfall and the total rainfall from the  
last cleared date,  
Pressure drop  
1. Press the rainfall window.  
High gust wind  
2. Press [MEMORY] for the desired record. Yesterday rainfall will  
bedisplayedwithYESTERDAYshownintherainfallwindow.  
Total rainfall will be displayed with "TOTAL" shown in the  
rainfall window. The time and date of the record will be displayed  
alternatively with SINCEicon in the clock window for total  
rainfall.  
Low wind chill  
To set a weather alarm,  
1. Press the window containing the weather element you want to  
set.  
2. Press [ALARM]. The current alarm setting will be displayed.  
3. Press and hold [SET].  
Note: Yesterdays rainfall record will be updated when the real time  
clock runs from 11:59:59 pm to 12:00:00 am. And it is counted for  
12:00:00 am of one day to 12:00:00 am on the next day.  
4. Press [U] and [V] for the desired setting.  
5. Press[SET].  
If the rain sensor detects no rainfall for about two consecutive  
hours, the current rate of rainfall will be displayed as zero.  
For temperatures and humidity, the high and low alarms can be set  
in sequence. After entering the value for one alarm, you will be  
prompted to enter the value for the other.  
To clear the total rainfall,  
A weather alarm is activated once set. When the set criteria is met,  
an alarm will go off and the current reading will flash together with  
the corresponding indicator.  
1. Press the rainfall window.  
2. Press and hold [MEMORY] till the key tone is heard.  
The yesterdays rainfall record will not be affected when you clear  
the total rainfall.  
If that happens in the outdoor/channel temperature or humidity  
window, the OUTindicator will flash to show that the criteria set  
for the outdoor thermo-hygrometer has been met. If it is one of the  
separate sensors, the [CHANNEL] indicator will flash. Press the  
window repeatedly to locate the channel in question.  
WIND SPEED AND DIRECTION  
The current wind speed and direction are displayed in the wind  
speed and direction window.  
When a weather alarm goes off, press any button to stop the alarm.  
The alarm is still active until you deactivate the function or the  
criteria is no longer met.  
To display the average wind speed, press the window till the  
AVERAGEicon is displayed.  
To do so,  
The wind speed can be displayed in m/s, kph, mph or knots.  
1. Press the window containing the weather element you want to  
set.  
To select the display unit,  
2. Press[ALARM].  
1. Press the wind speed and direction window.  
3. Press [ALARM ON/OFF] to deactivate the function.  
2. Press [UNIT] for the desired setting.  
To turn on the function again, simply follow the same procedure  
andpress[ALARMON/OFF].  
To display the maximum speed and direction for gust wind in  
record,  
1. Press the wind speed and direction window.  
2. Press [MEMORY]. The time and date of the record will also be  
displayed aternatively with STAMPicon in the clock window.  
6
928N-USE.p65  
6
08/10/2001, 12:20 PM  
 
( -4°F to 140°F )  
: 0.1°C (0.2°F)  
DISCONNECTED SIGNALS  
Resolution  
(indoor and outdoor)  
If without obvious reason the display for the main unit goes blank  
or “  
are displayed, press and hold [CHANNEL] to enforce an  
immediate search.  
Relative Humidity  
Measuring Range  
(indoor and outdoor)  
: 2 to 98% RH  
: 1%RH  
If that fails, check:  
-
-
All weather instruments are still in place.  
Resolution  
(indoor and outdoor)  
The batteries of the main unit and individual weather instruments  
are still good. Replace them if necessary. Press and hold  
[CHANNEL]toenforceanimmediatesearchafterwards.  
DewPointTemperature  
-
The transmission is within range and path is cleared of obstacles  
and interference. Shorten the distance if necessary.  
Measuring Range  
: Indoor ..... 0°C to 49°C  
( 32°F to 120.2°F )  
Then press and hold [CHANNEL] again. The main unit will start  
searching for all previously locked weather instruments.  
: Outoor ..... -10°C to 60°C  
( 14°F to 140°F )  
Resolution  
(indoor and outdoor)  
: 1°C (2°F)  
If you want to add an new sensor, press the reset button on the new  
sensor and then press channel to enforce the main unit to search.  
Note: 1. Do not reset the sensors after the main unit has locked  
those sensors, otherwise the main unit will no longer  
receive the signal from those sensors.  
Barometric Pressure / Trend  
Measuring Range  
: 795 to 1050 mb  
(23.48 to 31.01 inHg)  
2. If you have disconnected signals, you cannot clear the  
memory.  
Resolution  
: 1 mb (0.03 inHg)  
WindSpeed  
THE RESET BUTTON  
Measuring Range  
Resolution  
: 0 to 56 m/s (0 to 125.3 mph)  
: 0.2 m/s (0.4 mph) (typical)  
This button is only used when the system is operating in an  
unfavorable way or malfunctioning. Use a blunt stylus to hold  
down the button. The main unit will return to all default settings  
and start searching for signals again.  
Wind Direction  
Measuring Range  
Digital Resolution  
Graphical Resolution  
: 0° to 359° (Degrees)  
: 1° (typical)  
: 10°  
Before resetting the main unit, you should do the same for all  
weather instruments to ensure correct transmission and reception  
of signals. Then press reset on the main unit.  
WindChillTemperature  
Measuring Range  
Resolution  
MAINTENANCE  
: -52°C to 60°C (-61.6°F to 140°F)  
When handled properly, this unit is engineered to give you years  
of satisfactory service. Here are a few product care instructions:  
: 1°C (2°F)  
1. Do not immerse the unit in water. If the unit comes in contact  
with water, dry it immediately with a soft lint-free cloth.  
Rainfall  
Daily and Cumulative  
: 0 to 9999 mm (0 to 393.7 in)  
2. Do not clean the unit with abrasive or corrosive materials.  
Abrasive cleaning agents may scratch the plastic parts and  
corrode the electronic circuit.  
Measuring Range  
Rainfall Rate  
Measuring Range  
: 0 to 999 mm/hr (0 to 39.37 in/hr)  
: 1 mm (0.04 inch)  
3. Do not subject the unit to excessive: force, shock, dust,  
temperature, or humidity. Such treatment may result in  
malfunction, a shorter electronic life span, damaged batteries, or  
distorted parts.  
Daily and Cumulative  
Resolution  
Rainfall Rate Resolution : 1mm/hr (0.04 m/h) typical  
4. Do not tamper with the units internal components. Doing so  
will terminate the units warranty and may cause damage. The  
unit contains no user-serviceable parts.  
WMR968:  
Weight  
: 505 g  
Dimension  
Power  
: 204 (L) x 139 (W) x 39 (H)  
: 12V AC / DV adapter  
: 4 x UM3 - AAsize alkaline battery  
5. Only use new batteries as specified in this instruction manual.  
Do not mix new and old batteries as the old batteries may leak.  
Power backup  
6. Read this instruction manual thoroughly before operating the unit.  
WGR968 :  
Weight  
: 430 g  
SPECIFICATIONS  
Temperature  
Dimension  
Power  
: 295 (L) x 116.5 (W) x 550 (H)  
: solar cell (STR918)  
Proposed Operating Range : Indoor ..... -5°C to 50°C  
( 23°F to 122°F )  
: Outoor ..... -20°C to 60°C  
7
928N-USE.p65  
7
08/10/2001, 12:20 PM  
 
R&TTEComplianceNote  
THGR968 :  
Weight  
: 111.5 g  
This device complies with the essential requirements of Article 3  
of the R&TTE 1999/5/EC Directive, if used for its intended use and  
that the following standard(s) has been applied:  
Dimension  
Power : Main  
: 113.5 (L) x 42.5 (W) x 107.5 (H)  
: solar cell (STR918)  
RGR968:  
Weight  
Electromagnetic compatibility (Article 3.1.b of the R&TTE Direc-  
tive)  
: 276 g  
Dimension  
Power : Main  
: Ø 113.5 x 145 (H)  
: sole cell (STR918)  
Applied standards ETS 300 683 : 1997  
Efficient use of the radio frequency spectrum (Article 3.2 of the  
R&TTEDirective)  
BTHR968 :  
Weight  
: 78.4 g  
Applied standards EN300 220 1 : 1997  
Dimension  
Power  
: 180 (L) x 70 (W) x 19 (H)  
: 4 x UM4-AAAsizealkalinebattery  
INTENDED USE OF THE DEVICE  
STR928 :  
Weight  
: 266 g  
Dimension  
Power back up  
: 115 (L) x 81 (W) x 138 (H)  
: 2 x UM3- AAsize alkaline battery  
(recommend super lithium battery for  
weather condition under 32°F)  
CAUTION  
The content of this manual is subject to change without  
further notice.  
STR938 :  
Weight  
: 290 g  
Dimension  
Power back up  
: 115 (L) x 81 (W) x 138 (H)  
Due to printing limitation, the displays shown in this  
manual may differ from the actual display.  
: 2 x UM3- AAsize alkaline battery  
(recommend super lithium battery for  
weather condition under 32°F)  
The contents of this manual may not be reproduced  
without the permission of the manufacturer.  
NOTE ON COMPLIANCE  
Warning: Changes or modifications to this unit not expressly  
approved by the party responsible for compliance could void the  
users authority to operate the equipment.  
FCC :  
NOTE: This equipment has been tested and found to comply with  
the limits for a Class B digital device, pursuant to Part 15 of the  
FCC Rules. These limits are designed to provide reasonable  
protection against harmful interference in a residential installation.  
This equipment generates, uses and can radiate radio frequency  
energy and, if not installed and used in accordance with the  
instructions, may cause harmful interference to radio  
communications.  
However, there is no guarantee that interference will not occur in a  
particular installation. If this equipment does cause harmful  
interferencetoradioortelevisionreception, whichcanbedetermined  
by turning the equipment off and on, the user is encouraged to try  
to correct the interference by one or more of the following measures:  
Reorient or relocate the receiving antenna.  
Increase the separation between the equipment and receiver.  
Connect the equipment into an outlet on a circuit different from  
that to which the receiver is needed.  
Consult the dealer of an experienced radio/TV technician for  
help.  
8
928N-USE.p65  
8
08/10/2001, 12:20 PM  
 
CUSTOMER ASSISTANCE  
Should you have questions about this project or require additional  
assistance, please contact our 24-7-365 customer service department  
at 800-853-8883 or via email at [email protected].  
Product Name  
Model Number  
:
:
CABLE FREE WEATHER STATION  
WMR968  
Responsible Party : Oregon Scientific, Inc.19861 SW 95th Place Tualatin,  
Oregon 97062 USA  
Tel  
:
503-639-8883  
928N-USE.p65  
9
08/10/2001, 12:20 PM  
 

Miele Burner CS 1112 E User Manual
Miele Washer 09 845 470 User Manual
MTD Trimmer 700rVP User Manual
Napoleon Grills Gas Grill 600RB User Manual
NHT Speaker CS 61 Ci User Manual
Nokia Headphones BH 209 User Manual
Nortel Networks Telephone CallPilot 20 User Manual
Palm PDAs Smartphones Zire User Manual
Panasonic Telephone KX TC1220NZW User Manual
Panasonic VCR HD1700pe User Manual